Manage advanced settings

Learn how to change the Edge Portal advanced settings and understand how each value affects memory, processing, storage, and notification history.

Written by Mads Mikkelsen

Updated at September 10th, 2026

Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Please fill out the contact form below and we will reply as soon as possible.

  • Installation & Technical information
    Introduction SIA Connect Standalone SIA Connect Standalone Plus SIA Connect ANY-Ware Cellular & WiFi connectivity
  • Edge Portal (Next-gen)
    Getting started with the Edge Portal Workspace Configuration Instances Data Interfaces Tools
  • Connectors
    Industrial Connectors Databases Cloud Connectors
  • Scripting & Variables
    Data formatting Advanced Data Processing
  • Developers
    API documentation Shadow API
  • Tutorials & Guides
    InfluxDB AWS IoT Core - Amazon Web Services Microsoft Power BI KaaIoT Siemens S7 AVEVA Insight SIA Connect Demo Rack Grafana Notification & Messaging Azure Cumulocity MQTT MS SQL OPC-UA Server
  • General
  • Configuration in the Edge Portal (legacy)
    Getting started with the UI Connectors Instances Items Mapping Data System Network Tools & Add-ons DigiCert IoT Trust Manager Remote Access & VPN tunneling
+ More

Table of Contents

Open Advanced settings Change an advanced setting Understand the available settings Choose values carefully Troubleshoot Advanced settings Related articles

Articles in this section:

  • Install and manage Connectors
  • Manage and configure Connector files and certificates
  • Manage system settings and time
  • Manage advanced settings
  • Configure and review system logs
  • Restart SIA Connect
  • Activate and manage a license
  • Export and import configurations
  • Update the SIA Connect software
  • Change network settings in the Edge Portal
  • Manage users, roles, and permissions

Use Advanced settings to adjust how SIA Connect uses memory, processes data, protects free storage, and retains notification history.

These settings can affect performance, resource use, stored data, and software availability. Record the current value before changing it, and change one setting at a time so you can identify the effect.

 

 

Open Advanced settings

  1. Sign in to the Edge Portal.
  2. Expand Configuration in the sidebar.
  3. Select System.
  4. Expand Advanced settings if the section is collapsed.

The section displays the current value and unit for each available setting. If a setting has no value, the portal displays N/A.

 

Change an advanced setting

  1. Find the setting you want to change.
  2. Select its edit button, or double-click the setting row.
  3. Enter the new value. For settings that display a unit, enter the value without adding the unit text.
  4. Select the check button to save the value.
  5. Confirm that the editor closes and the updated value appears in the list.

Select the cancel button to discard the value you entered and keep the current setting.

The Edge Portal refreshes the Advanced settings list after a successful save. It does not display a restart prompt. If the SIA Connect API marks a setting as read-only, the edit button is not available and double-clicking the row has no effect.

 

Understand the available settings

Setting Unit What it controls What to consider before changing it
Historical data size Number of values Controls how many previous values are kept for each item and can be accessed with the %VALUE_HIST[nth]% variable. A larger history provides access to more previous values but uses more memory.
Worker wait interval ms Controls how long the software waits between processing data and checking for new data. A lower interval makes the worker check more often and increases CPU use. A higher interval reduces how often it checks.
Low space threshold MB Sets the free-storage threshold at which the system starts deleting data. Keep a safe storage buffer. For a SIA Connect hardware unit, the UI guidance specifies a minimum buffer of 1.5 GB.
Memory threshold kB Sets the free-memory threshold at which SIA Connect restarts the software to avoid problems caused by low available RAM. A value that is too high can cause unnecessary software restarts. A value that is too low leaves less memory available before the safeguard is triggered.
Internal write buffer Number of write commands Sets how many internal write commands can be held before they are flushed to the database. A larger buffer uses more memory.
Notification history age days Sets the maximum age of notification lifecycle events stored on the unit. An invalid or non-positive value uses the default of 90 days.
Notification history size events Sets the maximum number of notification lifecycle events stored on the unit. An invalid or non-positive value uses the default of 10,000 events.

 

Choose values carefully

The Edge Portal does not define numeric ranges or show field-specific validation rules for these settings. Use values appropriate for the gateway's workload and available resources.

  • Change one value at a time.
  • Keep a record of the original value.
  • Monitor CPU, memory, and storage on Workspace > Overview after changing a performance or resource setting.
  • Check the notification history after changing either notification-retention setting.
  • Avoid reducing the low-space buffer below the minimum shown in the UI guidance for SIA Connect hardware.

 

Troubleshoot Advanced settings

Message or condition What to do
Loading advanced settings... remains displayed Wait for the page to finish loading. If it does not finish, reload the page and check that the Edge Portal can communicate with the SIA Connect API.
Failed to load advanced settings. Reload the page. If the message returns, resolve any gateway or API communication warning before trying again.
No edit button is available The setting is read-only according to the SIA Connect API. It cannot be changed from this page.
Failed to save setting. Please try again. Check the entered value and try again. The UI does not provide a more specific validation message, so restore the previous value if the new value is not accepted.
The value is shown as N/A The setting was not returned by the API or its value is empty. Reload the page. If it remains unavailable, check the gateway software and API status.
A saved value does not appear Reload the page and check the setting again. If it still shows the previous value, enter it again and confirm the save button before leaving the editor.

 

Related articles

  • Manage system settings and time
  • Understand Edge Portal notifications
  • Configure and review system logs
  • Export and import configurations
advanced settings edge portal performance storage memory notification history system

Was this article helpful?

Yes
No
Give feedback about this article

Related Articles

  • Install and manage Connectors
  • Manage and configure Connector files and certificates
  • Manage system settings and time
  • Configure and review system logs
  • Restart SIA Connect

0
0
Expand