Supported Industrial & Buildings devices

Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Please fill out the contact form below and we will reply as soon as possible.

  • Getting started
    Introduction to SIA Technical info Portal - Web App (UI) SIA Connect as Software
  • Using SIA
    Connectors Instances Items Mapping Scripting & Variables Data
  • Connectors
    Siemens S7 Azure Ethernet/IP Mitsubishi MELSEC OPC-UA Server SQL MQTT Omron Host Link REST API Omron FINS Keyence Beckhoff TwinCAT BACnet Virtual OPC-UA Client MS SQL File
  • Developers
    API documentation Shadow API
  • Tutorials & Guides
    Azure IoT Hub Siemens S7 AWS IoT Core - Amazon Web Services Microsoft Power BI SIA Connect Demo Rack AVEVA Insight Azure IoT Central
+ More

Articles in this section:

  • Minimum requirements for using SIA
  • Get started with SIA Connect: A Step-By-Step guide
  • Supported Clouds & IoT messaging
  • Supported Industrial & Buildings devices
  • Supported databases
  • SIA Glossary

Table of Contents

StandardsPLC's & RTU's

SIA supports a large range of PLC vendors on proprietary protocols and open and standards protocols.

For more details of each protocol please visit their individual articles where you can also find information on how to configure them on SIA.


Standards

Standard Remarks
OPC-UA
Modbus TCP
Modbus RTU
BACnet IP
BACnet MS/TP
M-Bus Requires a M-Bus convert to RS232 or RS485 to be used for translating the physical signals.
M-Bus Wireless Requires a Wireless M-Bus receiver to be connected using the USB peripherals.  
The following modes are supported
  • C mode
  • S mode
  • T mode


PLC's & RTU's

Vendor Protocols & Devices Remarks
Siemens S7 *
  • 200**/300/400/1200/1500
S5 ***
LOGO!
Simatic TI505
Profibus ***
Connectors:
  • Siemens S7
  • Siemens LOGO!


* S7 only supports absolute addressing
** Using CP243 or similar ethernet module
*** S5 & Profibus support with adapter such as IBH Link S7++
Allen-Bradley ControlLogix
CompactLogix
MicroLogix
FlexLogix
Micro8xx
SLC500*
PLC5*
Connectors:
  • Ethernet/IP 


* Support using DH+ bridge

Omron Devices supporting FINS protocol and Host Link protocol. Connectors:
  • Omron FINS (UDP & TCP)
  • Omron Host Link
  • Ethernet/IP
Mitsubishi FX5 series
FX3 series
iQ-F series
iQ-R series
L series
QnA series
A series
Q series
Connectors
  • Mitsubishi MELSEC
Beckhoff TwinCAT 2
TwinCAT 3
BX9xxx
BC9xxx
Connectors
  • Beckhoff TwinCAT ADS
Schneider Devices supporting Modbus
Connectors:
  • Modbus TCP
  • Modbus RTU
ABB Devices supporting Modbus Connectors
  • Modbus RTU
  • Modbus TCP
Universal Robots Real-time Data Exchange (RTDE) Connectors
  • RTDE
CTi Control Technology Series 2500

Series 500

Connectors
  • CAMP / NITP
Keyence KV-3xxx
KV-5xxx
KV-700
KV-7xxx
KV-8xxx
KV Nano
Connectors
  • Keyence KV
  • Omron Host Link
  • Omron FINS
National Instruments TI505